5. Appendix 20 6/14/2010 4:13 PM
Setting the Starting Address
This DMX mode enables the use of a universal DMX controller device. Each fixture requires a start address
from 1~512. A fixture requiring one or more channels for control begins to read the data on the channel
indicated by the start address. For example, a fixture that uses six DMX channels and was addressed to start
on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, and 105. Choose start
addresses so that the channels used do not overlap, and note the start address selected for future reference.
If this is your first time addressing a fixture using the DMX control protocol, we suggest jumping to the
“Appendix” section and reading the heading “DMX Primer”. It contains very useful information that will help you
understand its use.
General Troubleshooting
S
YMPTOM
P
OSSIBLE
C
AUSE
(
S
) P
OSSIBLE
A
CTION
(
S
)
Breaker/Fuse
keeps blowing
Excessive circuit load Check total load placed on the electrical circuit.
Short circuit along the power
wires
Check for a short in the electrical wiring (internal and/or
external)
Device does not
power up
No power Check for power on power outlet
Loose power cord Check power cord
Fixture is not
responding to
DMX
Wrong DMX addressing Check Control Panel and unit addressing
Damaged DMX cables Check DMX cables
Wrong polarity settings on the
controller
Check polarity switch settings on the controller
Loose DMX cables Check cable connections
Faulty DMX interface Replace DMX input
Faulty Main PCB Replace Main PCB
Loss of signal
Non DMX cables Use only DMX compatible cables
Bouncing signals Install terminator as suggested
Long cable / Low level signal Install amplifier right after fixture with strong signal
Too many fixtures Install an optically coupled DMX splitter after unit #32
Interference from AC wires Keep DMX cables separated from power cables or
black lights
If you still have a problem after trying the above solutions, please contact CHAUVET Technical
Support.
Contact Us
World Wide
General Information CHAUVET®
3000 North 29
th
Court
Hollywood, FL 33020
voice: 954.929.1115
fax: 954.929.5560
toll free: 800.762.1084
Technical Support CHAUVET®
3000 North 29
th
Court
Hollywood, FL 33020
voice: 954.929.1115 (Press 4)
fax: 954.929.5560 (Attention: Service)
World Wide Web www.chauvetlighting.com
Vista de pagina 19
1 2 ... 15 16 17 18 19 20 21 22

Comentarios a estos manuales

Sin comentarios