6. GENERAL TROUBLESHOOTING
Symptom
Possible
Cause
Indicator
Status
Possible Action
No output or short output
Line blockage
or air in fluid
line
Orange
Make sure there is fluid in the tank
Turn fog machine 45° to flatten out the bubble
and allow the fog fluid to flow properly
Prime by setting output to the highest setting
Turn off the product for 5 seconds, and then turn it
back on. Repeat as necessary.
Note: After more than 10 attempts, contact
Incorrect fluid Off
Clean thoroughly with CHAUVET® FCQ. For full
instructions, see Fogger Maintenance. Refill with
CHAUVET® water-based haze fluid.
No output or spitting fluid
Incorrect fluid
Off
Clean thoroughly with CHAUVET® FCQ. For full
instructions, see Fogger Maintenance
. Refill with
CHAUVET® water-based haze fluid.
Fuse keeps blowing
Excessive load on the circuit
Make sure that the total load does not exceed
80% of the breaker or fuse nominal current
Short circuit along the power
Check the power lines and power cords
Product does not power up
No energy on power outlet
Check power outlet
Loose or damaged power cord
Blown fuse
Replace blown fuse with a good one of the same
Product stops pumping/ Loud
noise
Refill product with fluid
Pump protection system
engaged
Release manual fog button, and press it again to
reset pump protection system
If you still experience problems after trying the solutions presented here, contact
Chauvet Technical Support. See Contact Us.