Scorpion™ Storm FXRG User Manual 15 Rev. 3
Troubleshooting
Symptom Solution(s)
Check fan thermal switch reset
Beam is very dim or
not bright
Clean optical system or replace lamp
Check 220/110 v switch for proper setting
Breaker/Fuse keeps
blowing
Check total load placed on device
Check for power on Mains
Check device’s fuse (internal and/or external)
responding
Check DMX Dip switch settings for correct addressing
Check DMX cables
Check polarity switch settings
there is no
movement to the
Make sure you have the correct audio mode on the
control switches. If audio provided via ¼″ jack, make
sure a live audio signal exists
Adjust sound sensitivity knob
Lamps cuts off
sporadically
Possible bad lamp or fixture is overheating
Lamp may be at end of its life
on after power failure
Some discharge lamps require a cooling off period
before the electronics in the fixture can kick start it
again, wait 5 to 10 minutes before powering up
Install terminator
Note: Keep DMX cables separated from power cables
Check 220/110v switch for proper setting
Re-install bulb, may have shifted in shipping
Bounce mirror motor may have shifted during shipping,
readjust
All Chauvet® lighting fixtures featuring standalone
functions do not require additional settings, simply
power the fixture on and it will automatically enter into
this mode
If you still have a problem after trying the above solutions, please contact CHAUVET® Technical Support.